FireFly®, >1.5GHz, >180dB CMRR, ±60kV
The FireFly® high voltage optically isolated probe offers industry leading performance that combines the ability to accurately resolve high bandwidth, small differential signals in the presence of large common mode voltages with its ultra-high common mode rejection performance across its entire bandwidth. With >1.5GHz bandwidth, wide differential input range, unmatched common mode rejection ratio CMRR up to >180dB (1 billion to 1 rejection), and a 60kV common mode, FireFly® is the ideal measurement solution for both GaN and SiC device characterization and system level design development.
PMK‘s optically isolated interface and unique compact angled probe head design are the key attributes that set FireFly® apart from the other solutions in the market, providing very stable and accurate measurements over a wide temperature range and easy access to the measurement points in tight spaces.
The compact angled probe head design allows for shorter tip cables to be used, resulting in higher signal fidelity measurements and reduced stresses placed on the measurement test point. FireFly®‘s wide selection of probe tip connections and accessories offer reliable, hands-free, high-fidelity connectivity to the measurement points. Using industry standard MMCX and square pins connections allow FireFly® to easily interface to test boards that have already been design with these test points.
FireFly® has a universal BNC output connector and is compatible with any oscilloscope with a 50Ω input impedance or 1MΩ input impedance and a 50Ω feed-through termination, allowing FireFly® to be used on any oscilloscope in the lab.
For accurate deskew, each probe‘s unique propagation delay is measured and added to each probe label.
The FireFly® probe head is powered by an easy to change, rechargeable, industry standard 18650 battery that provides continuous operation for up to 30h at room temperature. The interface box is powered by the required PMK power supply. The 2ch PS2 and 4ch PS3 power supplies all have remote control capabilities and therefore a USB interface and optional additional LAN interface. As an alternative for most flexible use, the 1 channel battery pack power supply AP-01 provides >8h of portable and isolated operation but has no software remote control.
FireFly® series has the capability to be controlled from either remote control or the controls located on the interface box.
FireFly® Series’ DC offset can be controlled via remote control.
A PMK power supply unit is required. These are available with a USB interface and are optionally available with a LAN interface. Remote control of the probe is made possible by the power supply unit.
The exact range of functions of the probes is described on the page linked below for the respective software solution.
Several software solutions are available for remote control of PMK products:
ISO17025 calibration upon delivery or as re-calibration is possible on request.
Step 1: Select Base Probe
| Image | Notepad | Article | Attenuation | Bandwidth (-3 dB) | Input Voltage | Input Impedance | Rise time |
|---|---|---|---|---|---|---|---|
FF-0600A FireFly®, SMA Input | 1:1 | >600 MHz | ±1 V | 200 kΩ || 5.1 pF | <580 ps | ||
FF-1000A FireFly®, SMA Input | 1:1 | >1.0 GHz | ±1 V | 200 kΩ || 5.1 pF | <350 ps | ||
FF-1500A FireFly®, SMA Input | 1:1 | >1.5 GHz | ±1 V | 200 kΩ || 5.1 pF | <250 ps | ||
FF-1500A-10m FireFly®, SMA Input | 1:1 | >1.5 GHz | ±1 V | 200 kΩ || 5.1 pF | <250 ps |
Step 2: Select Probe Tip Cables
| Image | Notepad | Article | Attenuation | Bandwidth (-3 dB) | Input Voltage | Input Impedance | Rise time |
|---|---|---|---|---|---|---|---|
FF-MMCX-1V FireFly®, probe tip cable, MMCX | 1:1 | >1.5 GHz | ±1 V | 50 Ω * | <250 ps | ||
FF-MMCX-10V FireFly®, probe tip cable, MMCX | 10:1 | >1.3 GHz | ±10 V | 2 MΩ || 3.4 pF | <280 ps | ||
FF-MMCX-25V FireFly®, probe tip cable, MMCX | 25:1 | >1.3 GHz | ±25 V | 4,9 MΩ || 2.1 pF | <280 ps | ||
FF-MMCX-50V FireFly®, probe tip cable, MMCX | 50:1 | >1.3 GHz | ±50 V | 10 MΩ || 2 pF | <280 ps | ||
FF-MMCX-100V FireFly®, probe tip cable, MMCX | 100:1 | >1.3 GHz | ±100 V | 9.5 MΩ || 2.1 pF | <280 ps | ||
FF-MMCX-250V FireFly®, probe tip cable, MMCX | 250:1 | >1.3 GHz | ±250 V | 20 MΩ || 2.1 pF | <280 ps | ||
FF-WSQ-500V FireFly®, probe tip cable, WSQ | 500:1 | >1 GHz | ±500 V | 40 MΩ || 2.8 pF | <300 ps | ||
FF-WSQ-1000V FireFly®, probe tip cable, WSQ | 1000:1 | >1 GHz | ±1000 V | 40 MΩ || 2.9 pF | <300 ps | ||
FF-WSQ-1500V FireFly®, probe tip cable, WSQ | 1500:1 | >1 GHz | ±1500 V | 40 MΩ || 2.7 pF | <300 ps | ||
FF-WSQ-2500V FireFly®, probe tip cable, WSQ | 2500:1 | >1 GHz | ±2500 V | 40 MΩ || 2.5 pF | <300 ps | ||
coming soon: More connectivity solutions | |||||||
(*) terminated, 50Ω transmission line |
Step 5: Select Power Supply
| Image | Notepad | Article | Input Voltage | Output Current (max.) | Noise* | Channels | Output Voltage | Power | Immunity |
|---|---|---|---|---|---|---|---|---|---|
889-09V-PS2 2ch Power supply for remote control with USB interface | 90-240 V AC, 47-63 Hz | 0.5 A DC continuous | 5 mV RMS | 2 | ± 9 V | 20 W | IEC/EN 60601-1 - EN55011-B | ||
889-09V-PS2-L 2ch Power supply for remote control with USB and LAN interface | 90-240 V AC, 47-63 Hz | 0.5 A DC continuous | 5 mV RMS | 2 | ± 9 V | 20 W | IEC/EN 60601-1 - EN55011-B | ||
889-09V-PS3 4ch Power supply for remote control with USB interface | 90-240 V AC, 47-63 Hz | 0.5 A DC continuous | 5 mV RMS | 4 | ± 9 V | 40 W | IEC/EN 60601-1 - EN55011-B | ||
889-09V-PS3-L 4ch Power supply for remote control with USB and LAN interface | 90-240 V AC, 47-63 Hz | 0.5 A DC continuous | 5 mV RMS | 4 | ± 9 V | 40 W | IEC/EN 60601-1 - EN55011-B | ||
889-09V-PS6 8ch Power supply for remote control with USB interface | 90-240 V AC, 47-63 Hz | 0.5 A DC continuous | 8 mV RMS | 8 | ± 9 V | 60 W | IEC/EN 60601-1 - EN55011-B | ||
889-09V-PS6-L 8ch Power supply for remote control with USB and LAN interface | 90-240 V AC, 47-63 Hz | 0.5 A DC continuous | 8 mV RMS | 8 | ± 9 V | 60 W | IEC/EN 60601-1 - EN55011-B | ||
889-09V-AP01 1ch Battery pack, >8hrs operation, no remote control | 700 mA DC | 1 | ± 9 V | 20 W | |||||
890-520-900 Probe connection cable 0.5 m ** | |||||||||
890-520-915 Probe connection cable 1.5 m | |||||||||
(*) Bandwidth 20 MHz limited | |||||||||
(**) included in the scope of delivery |